429 research outputs found

    Contour Detector and Data Acquisition System for the Left Ventricular Outline

    Get PDF
    A real-time contour detector and data acquisition system is described for an angiographic apparatus having a video scanner for converting an X-ray image of a structure characterized by a change in brightness level compared with its surrounding into video format and displaying the X-ray image in recurring video fields. The real-time contour detector and data acqusition system includes track and hold circuits; a reference level analog computer circuit; an analog compartor; a digital processor; a field memory; and a computer interface

    Real-time detection and data acquisition system for the left ventricular outline

    Get PDF
    To automate the data acquisition procedure, a real-time contour detection and data acquisition system for the left ventricular outline was developed using video techniques. The X-ray image of the contrast-filled left ventricle is stored for subsequent processing on film (cineangiogram), video tape or disc. The cineangiogram is converted into video format using a television camera. The video signal from either the TV camera, video tape or disc is the input signal to the system. The contour detection is based on a dynamic thresholding technique. Since the left ventricular outline is a smooth continuous function, for each contour side a narrow expectation window is defined in which the next borderpoint will be detected. A computer interface was designed and built for the online acquisition of the coordinates using a PDP-12 computer. The advantage of this system over other available systems is its potential for online, real-time acquisition of the left ventricular size and shape during angiocardiography

    Dedicated bifurcation analysis: basic principles

    Get PDF
    Over the last several years significant interest has arisen in bifurcation stenting, in particular stimulated by the European Bifurcation Club. Traditional straight vessel analysis by QCA does not satisfy the requirements for such complex morphologies anymore. To come up with practical solutions, we have developed two models, a Y-shape and a T-shape model, suitable for bifurcation QCA analysis depending on the specific anatomy of the coronary bifurcation. The principles of these models are described in this paper, as well as the results of validation studies carried out on clinical materials. It can be concluded that the accuracy, precision and applicability of these new bifurcation analyses are conform the general guidelines that have been set many years ago for conventional QCA-analyses

    Three-dimensional reconstruction of myocardial contrast perfusion from biplane cineangiograms by means of linear programming techniques

    Get PDF
    The assessment of coronary flow reserve from the instantaneous distribution of the contrast agent within the coronary vessels and myocardial muscle at the control state and at maximal flow has been limited by the superimposition of myocardial regions of interest in the two-dimensional images. To overcome these limitations, we are in the process of developing a three-dimensional (3D) reconstruction technique to compute the contrast distribution in cross sections of the myocardial muscle from two orthogonal cineangiograms. To limit the number of feasible solutions in the 3D-reconstruction space, the 3D-geometry of the endo- and epicardial boundaries of the myocardium must be determined. For the geometric reconstruction of the epicardium, the centerlines of the left coronary arterial tree are manually or automatically traced in the biplane views. Next, the bifurcations are detected automatically and matched in these two views, allowing a 3D-representation of the coronary tree. Finally, the circumference of the left ventricular myocardium in a selected cross section can be computed from the intersection points of this cross section with the 3D coronary tree using B-splines. For the geometric reconstruction of the left ventricular cavity, we envision to apply the elliptical approximation technique using the LV boundaries defined in the two orthogonal views, or by applying more complex 3D-reconstruction techniques including densitometry. The actual 3D-reconstruction of the contrast distribution in the myocardium is based on a linear programming technique (Transportation model) using cost coefficient matrices. Such a cost coefficient matrix must contain a maximum amount of a priori information, provided by a computer generated model and updated with actual data from the angiographic views. We have only begun to solve this complex problem. However, based on our first experimental results we expect that the linear programming approach with advanced cost coefficient matrices and computed model will lead to a

    New approaches for the assessment of vessel sizes in quantitative (cardio-)vascular X-ray analysis

    Get PDF
    This paper presents new approaches for the assessment of the arterial and reference diameters in (cardio-)vascular X-ray images, designed to overcome the problems experienced in conventional quantitative coronary and vascular angiography approaches. In single or “straight” vessel segments, the arterial and reference diameter directions were made independent of each other in order to be able to measure the minimal lumen diameter (MLD) more accurately, especially in curved vessel segments. For ostial segments, an extension of this approach was used, to allow measurement of ostial lesions in sidebranches more proximal than using conventional methods. Furthermore, two new bifurcation approaches were developed. The validation study shows that the straight segment approach results in significant smaller MLDs (on average 0.032 mm) and the ostial approach achieves on average an increase in %DS of 3.8% and an increase in lesion length of 0.59 mm due to loosening the directional constraint. The validation of our new bifurcation approaches in phantom data as well as clinical data shows only small differences between pre- and post-intervention measurements of the reference diameters outside the bifurcation core (errors smaller than 0.06 mm) and the bifurcation core area (errors smaller than 1.4% for phantom data). In summary, these new approaches have led to further improvements in the quantitative analyses of (cardio-)vascular X-ray angiographies

    IgG Antibodies against Measles, Rubella, and Varicella Zoster Virus Predict Conversion to Multiple Sclerosis in Clinically Isolated Syndrome

    Get PDF
    BACKGROUND:Multiple sclerosis (MS) is characterized by a polyspecific B-cell response to neurotropic viruses such as measles, rubella and varicella zoster, with the corresponding antibodies measurable in CSF as the so-called "MRZ reaction" (MRZR). We aimed to evaluate the relevance of MRZR to predict conversion of patients with clinically isolated syndrome (CIS) to MS, and to compare it to oligoclonal bands (OCB) and MRI. METHODOLOGY/PRINCIPAL FINDINGS:MRZR was determined in a prospective study over 2 years including 40 patients that remained CIS over follow-up (CIS-CIS) and 49 patients that developed MS (CIS-RRMS) using ELISA. Using logistic regression, a score (MRZS) balancing the predictive value of the antibody indices included in MRZR was defined (9 points measles, 8 points rubella, 1 point varicella zoster, cutpoint: sum of scores greater 10). MRZR and MRZS were significantly more frequent in CIS-RRMS as compared to CIS-CIS (p=0.04 and p=0.02). MRZS showed the best positive predictive value (PPV) of all parameters investigated (79%, 95%-CI: 54-94%), which could be further increased by combination with MRI (91%, 95%-CI: 59-99%). CONCLUSIONS/SIGNIFICANCE:Our data indicate the relevance of MRZR to predict conversion to MS. It furthermore shows the importance of weighting the different antibody indices included in MRZR and suggest that patients with positive MRZR are candidates for an early begin of immunomodulatory therapy

    Summary of cerebrospinal fluid routine parameters in neurodegenerative diseases

    Get PDF
    In neurodegenerative diseases, cerebrospinal fluid analysis (CSF) is predominantly performed to exclude inflammatory diseases and to perform a risk assessment in dementive disorders by measurement of tau proteins and amyloid beta peptides. However, large scale data on basic findings of CSF routine parameters are generally lacking. The objective of the study was to define a normal reference spectrum of routine CSF parameters in neurodegenerative diseases. Routine CSF parameters (white cell count, lactate and albumin concentrations, CSF/serum quotients of albumin (Qalb), IgG, IgA, IgM, and oligoclonal IgG bands (OCB)) were retrospectively analyzed in an academic research setting. A total of 765 patients (Alzheimer’s disease (AD), Parkinson’s disease (PD), Parkinson’s disease dementia (PDD), vascular dementia (VD), frontotemporal lobar degeneration (FTLD), progressive supranuclear palsy (PSP), multisystem atrophy (MSA), motor neuron diseases (MND), spinocerebellar ataxia (SCA), Huntington’s disease (HD)) and non-demented control groups including a group of patients with muscular disorders (MD). The main outcome measures included statistical analyses of routine CSF parameters. Mildly elevated Qalb were found in a small percentage of nearly all subgroups and in a higher proportion of patients with PSP, MSA, VD, PDD, and MND. With the exception of 1 MND patient, no intrathecal Ig synthesis was observed. Isolated OCBs in CSF were sometimes found in patients with neurodegenerative diseases without elevated cell counts; lactate levels were always normal. A slightly elevated Qalb was observed in a subgroup of patients with neurodegenerative diseases and does not exclude the diagnosis. Extensive elevation of routine parameters is not characteristic and should encourage a re-evaluation of the clinical diagnosis

    Introduction to hemodynamic forces by echocardiography

    Get PDF
    Hemodynamic force (HDF) analysis represents a novel approach to quantify intraventricular pressure gradients, responsible for blood flow. A new mathematical model allows the derivation of HDF parameters from routine transthoracic echocardiography, making this tool more accessible for clinical use. HDF analysis is considered the fluid dynamics correlate of deformation imaging and may be even more sensitive to detect mechanical abnormalities. This has the potential to add incremental clinical value, allowing earlier detection of pathology or immediate evaluation of response to treatment. In this article, the theoretical background and physiological patterns of HDF in the left ventricle are provided. In pathological situations, the HDF pattern might alter, which is illustrated with a case of ST segment elevation myocardial infarction and non-ischemic cardiomyopathy with typical left bundle branch block

    Measles IgG Antibody Index Correlates with T2 Lesion Load on MRI in Patients with Early Multiple Sclerosis

    Get PDF
    Background: B cells and humoral immune responses play an important role in the pathogenesis and diagnosis of multiple sclerosis (MS). A characteristic finding in patients with MS is a polyspecific intrathecal B cell response against neurotropic viruses, specifically against measles virus, rubella virus, and varicella zoster virus, also known as an MRZ reaction (MRZR). Here, we correlated from the routine clinical diagnostics individual IgG antibody indices (AIs) of MRZR with magnetic resonance imaging (MRI) findings in patients with first MS diagnosis. Methods/Results: MRZR was determined in 68 patients with a clinically isolated syndrome (CIS) or early relapsing-remitting MS (RRMS). Absolute AI values for measles virus, rubella virus, and varicella zoster virus were correlated with T2 lesion load and gadolinium enhancing lesions on cerebral MRI (cMRI) and cMRI combined with spinal MRI (sMRI). Measles virus AI correlated significantly with T2 lesion load on cMRI (p = 0.0312, Mann-Whitney U test) and the sum of lesions on cMRI and sMRI (p = 0.0413). Varicella zoster virus AI also showed a correlation with T2 lesion load on cMRI but did not reach statistical significance (p = 0.2893). Conclusion: The results confirm MRZR as part of the polyspecific immune reaction in MS with possible prognostic impact on MRI and clinical parameters. Furthermore, the data indicate that intrathecal measles virus IgG production correlates wit

    Novel clinical applications of state-of-the-art multi-slice computed tomography

    Get PDF
    Recent years have witnessed a rapid development of multi-slice computed tomography (MSCT) technology. The number of detector rows has increased from 4-slices to the current availability of 64-slice and even 320-slice systems. In addition, images are acquired with thinner slices and faster rotation times resulting in substantially improved image quality and diagnostic accuracy. Simultaneously, effective dose reduction acquisition techniques have been developed allowing considerable reduction of the radiation dose. Conceivably, these advancements may allow further expansion of the use of MSCT beyond the visual assessment of the presence or absence of significant coronary artery disease. Indeed, a particular advantage of the technique is that in addition to evaluation of the coronary arteries it also allows assessment of cardiac structures and function. The purpose of the current review is to discuss several novel applications of cardiac MSCT, including stenosis quantification, atherosclerotic plaque imaging and prognostification as well as imaging of left ventricular function, aortic and mitral valve anatomy using state-of-the-art technology
    corecore